molecular devices 384 well plate reader. Contains a revised proprietary masking dye with higher light extinction in the extracellular solution to significantly reduce background and increase signal window. molecular devices 384 well plate reader

 
 Contains a revised proprietary masking dye with higher light extinction in the extracellular solution to significantly reduce background and increase signal windowmolecular devices 384 well plate reader  20 attomol ATP per well

1 or 10 Tablet PC with USB connection to instrument: Read Speed: 96-well plate: less than 1 minute; 384-well plate: less than 3 minutes: Automation Compatibility: Hardware and software accessible to third-party hardware/software control, including LIMS. 6-well tissue-culture treated (TC) plate, sterile. Products : FlexStation 3 reader, SpectraMax M5/M5e reader, SpectraMax M2/M2e reader Multimode Readers Comparison Chart. " A versatile UV/VIS spectrophotometer for both 96- and 384-well. The SpectraMax® i3x Multi-Mode microplate reader measures spectral-based Absorbance, Fluorescence, and Luminescence with the added functionality of modular upgrades for. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the. SpectraMax® iD5 Multi-Mode Microplate Readers,6 to 384-Well Microplates, Molecular Devices, LLC (CAT#: STEM-LE-0504-LC) Product Keyword. Growth medium was then replaced with fatty acid uptake solution. #3-000-510)Page 154: Ordering Parts And Accessories. The FilterMax™ F3 features absorbance (visible), fluorescence intensity - FI (top reading), and glow luminescence for 96- to 384-well plates. Monitor reader performance on demand to ensure data quality is not compromised between PM/OQ. 1: The SPECTRAmax 340PC 384 System The on-board microprocessor calculates and reports the absorbance (or % Transmittance) for each well of a microplate. Bioz Stars score: 86/100, based on 9 PubMed citations. Spectranet customer portalThe microplate reader has been around for more than three decades and continues to serve as a must-have workhorse of clinical, academic research and industrial laboratories alike. Data for a 384-well plate can be collected in less than two minutes, as opposed to up to 30The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. Temperature Control: ambient from +4 to 45C. USA. 384-Deep Square Well Plates. M2. The screw remains inside the instrument. If you have an xml plate object, then. 96-384. Option 1: Use a plate. 5 mm left a residual volume of 100 µL in each well of a 96-well plate or 25 µL for a 384-well plate. • The FlexStation™ II³⁸⁴ instrument is designed for 96- and 384-well microplates. 4 Equipment. 96 Well Plate Reader found in: Well Plate Reader Accessory, SmartReader™ 96 Microplate Absorbance Reader, SmartReader UV-Vis Microplate Reader, Stratus. No. Was the failure only of the Detection Estimate (Mag3) Test for the M3/M4/M5/M5e/Flex3?Gurard-Levin describes his lab’s microplate reader selection: “In our labs, specific and refined optics are important, as well as the ability to use high density plates including those with 384- or 1536-wells. The narrow bandwidths used by the model increase measurement accuracy and linearity over a wide. MultiWash+ Microplate Washer. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. For more sample throughput, the system canSpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384. book Page 1 Wednesday, October 12, 2011 4:56 PMSpectraMax Plus 384 Microplate Reader (Molecular Devices cat. Microplates, cuvettes (via adapter) Detectors. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. For the 96-well plate, this equates to 1 fg per well to 1 ng per well; for the 384-well plate it is 0. $542. SpectraMax ABS Plus Microplate Reader (Molecular Devices cat. SpectraMax Paradigm Microplate Reader General specifications User-upgradeable Multi-Mode Detection Platform Technical specifications Optimized Guaranteed* Fluorescence Intensity (FI) (Fluorescein) 96-well (200 µL) 0. 20 attomol ATP per well. 315 can't find zero order. Overview. Documentation Computer Integration Each Molecular Devices microplate reader is shipped with a license key for the SoftMax® Pro Data Acquisition and Analysis Software that you install on the computer that you use to operate the instrument. Top. Plates were read in the SpectraMax M5 microplate reader at 485ex/515em with bottom read. CAPABILITIES OF THE EQUIPMENT: The high sensitivity, low-noise photomultiplier tubes (PMTs), and variable-volume injector configuration make this reader ideal for fast kinetic assays requiring. For more sample throughput, both readers can be easily. x. Molecular Devices deliver high throughput while showing good correlation with manual patch clamping data. Microplate format. Loading Buffer was also added to a set of cell-free wells for background controls. 0 OD for earlier models. Packed 25 plates per sleeve, 2 sleeves per case. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. 100 ˜L (96-well) or 25 ˜L (384-well) of Loading Buffer was added to each assay well. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. Microplate Spectrophotometer. luminescence for a 96-well plate and 40 msec integration time for a 384-well plate: 0517 Lit. xABS2, FL1, and LM1 Validation Plates sent to Molecular Devices for recertification at our ISO 17025 accredited lab are disassembled, cleaned, calibrated, an then returned with a new certificate of calibration. Industry standard disposable (choose from recommended list). 96-deep-round-well-plate, 384-deep-square-well-plate, 24-deep-well-plates. Supersedes 1. The absorbance was then read on the SpectraMax microplate reader at 426 nm, and the resulting OD values for all wells were averaged together to obtain a value of 0. Calcium flux was measured with a FlexStation 3 Microplate Reader using the Flex (fast kinetic) read type. 984. In addition, SoftMax Pro SoftwareSpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384. x. ,LTD (CAT#: STEM-S. To maximize sensitivity of the assay, it is necessary to use optimal excitation and emission wavelengths. VIS absorbance detection. 0 and dispense 10 μL to all wells of the 384-well plate(s) (see Note 13). The Standard Thermo Scientific 384-well plate, Barcoded, White, is compatible with the majority of 384 block PCR and sequencing instruments. Can read 96 well plates (optional 384 well). Fastest Read Time - 96-well plate: 20 sec; 384-well plate: 30 sec. x. Based on this customer experience and feedback, the Infinite 200 PRO microplate plate reader has been continuously engineered for. M2. To ensure accurate cell numbers for the cell standard curves, cells were assayed immediately. For more sample throughput, the system canThe SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. Wash heads are made of Polyethylene Terephthlate (PET) with stainless steel probes to prevent corrosion. PURPOSE. 40266. Use standard plate unless you see your type listed. the use of a reader calibrated with primary NIST and NMI standards. 96- and 384-well. 384 Well Plates; Wavelength(s): 200 to 1000 nm (Abs), 250 - 850 nm (Fluor) Specifications/Features: Shaking, Temperature control, Cuvette port; Read More. For a higher . Related products. Ideal for miniaturized 384 well fluorescent. The reader adds up to three transfers of assay reagents from a 96- or 384-well source plate to enhance assay design using integrated fluidics. flat meniscus), but is approx 15 mL. A. within each well. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time. An IL-22 standard curve was prepared and a sandwich ELISA performed using the MultiWash+ plate washer in strip mode to wash the wells. x. Key benefits • Assess cell confluence objectively and quantitatively. FlexStation 3 Benchtop Multi-Mode Microplate Reader User Guide Ordering Parts and Accessories To obtain parts and accessories, contact Molecular Devices Customer Service or your authorized service representative. This chapter reviews key criteria for microplate selection, including: well number, well volume and shape,. 003 fmol 0. in every plate. x. SoftMax® Pro Microplate Data Acquisition and Analysis Software Version 6 User Guide 5014177 C October 2011 FrameMaker_Export. Features. We also prefer that fluorescence signals in one well don’t bleed into the other, as this means less background and more precise data. 012 fmol 0. 더 많은. X. research needs. Made from polypropylene with conical well profiles to maximize recovery and allow working with sample volumes as low as 5 µL. 0 OD for our latest microplate readers, SpectraMax® iD3, iD5, ABS, and ABS Plus readers, and up to 2. UV absorbance detection. The drawing shows a standard microplate of 15 mm height covered with a lid. SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner robots. 190. 96-Deep Round or Square Well Plates. x. Catalog number: AB1384W. Pro, Dual Read mode was selected. SLS & DLS: 2 µL quartz cuvettes 45 µL quartz cuvettes 4 mL generic glass cuvette DLS only:Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. Suggested plates are black. #S1205. 20 µL (96-well plates) or 10 µL (384-well plates. 96/384 - For the SpectraMax 340PC384, press to select to read a 96-well plate or a 384- well plate. NanoQuant plate. The user must ensure that the meniscus is comfortably above the light beam in standard cuvettes and that the sample chamber in a microcuvette is aligned properly with the beam. x. After incubation, the assay plate is transferred to the seal-peeler to remove the seal from the assay plate and transferred to washing. Fluorometers also vary in the size of samples they accept, with some using very small sample sizes to conserve precious sample materials (down to 0. Integrate any SpectraMax Multi-Mode Reader with the StakMax Microplate Handling System from Molecular Devices. and the A1 corner of the plate adapter (Figure 1-2). For more sample throughput, the system can384 Well Plate, supplied by Molecular Devices LLC, used in various techniques. Two high-energy xenon flash lamps: Reading capabilities. The LMax plate reader has similar calculations and its RLUs are comparable to those of LMax II 384. Instrument pricing. Integrated stacker option. Embla washers are durable and easy to maintain. Products : Ionworks HT, Ionworks Quattro. NORTH AMERICA +1 800-635-5577 Mon to Fri 7am - 5pm Pacific Time. The microplate was then placed in a SpectraMax. 2. SpectraMax ID5 Plate Reader (Molecular Devices). All stand-alone instrument functions can be controlled using the software. The SpectraMax Paradigm reader with HTRF Detection Cartridge offers high-throughput screening capability with excellent read times and Z’ factors. or use the modified protocol below for the generation of NPCs (see Note 1). Microplate readers can be used to quantify this turbidity to monitor events such as cell growth or to perform solubility screens. SpectraMax M Series Multi-Mode Microplate Readers Molecular Devices LLC Applications: Absorbance, Cell Health, Cell Viability, Cellular. However, for greater flexibility, some instruments can accommodate 6- to 1536-well plate formats. Step 1: Open the SoftMax Pro IMAP FP protocol. SpectraMax i3x Multi-Mode Microplate Reader (Molecular Devices cat. A Costar® 24-well tissue culture plate with col1 = blanks and doubling cell concentration left to right starting at Col. 96-1536. Abs). It has a. 0112-0126B 8 Chapter1:Introduction TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. On the FlexStation 3 reader, the entire series of reactions is monitored in real time with simultaneous on-board reagent pipetting and luminescence detection (Figure 1). VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Ensure your assay quality with quality tips Certified RNase-/DNase-free Nonpyrogenic Nonsterile 50 racks/case. For more sample throughput, the system canabsorbance plate readers. The approximate dead volumes are: 96-well plates: V-bottom: 20-30 µl. Page 2 SpectraMax ® SpectraMax ® Multimode Plate Readers User Guide Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089. F3/F5 Multi-Mode Microplate ReadersBoth reactions can be easily measured in Molecular Devices’ new SpectraMax® L microplate luminometer. Microplate Formats: 6, 12, 24, 48, 96, 384. Fluorescent reading data were analyzed by non-linear fitting (GraphPad Prism, GraphPad Software Inc. the iD5 reader’s filter system. Application Area: Multi mode plate reader. 0 mm Holex HEXAGON ballhead bolt driver to loosen the screw located inside the Transport Lock opening until you feel the spring release. To maintain confidence in the standards, Molecular Devices recommends having validation plates recertified at one-to Molecular Devices for recertification at our ISO 17025 accredited lab are disassembled, cleaned, calibrated, andSpectraMax® iD5 Multi-Mode Microplate Readers,6 to 384-Well Microplates, Molecular Devices, LLC (CAT#: STEM-LE-0504-LC) Product Keyword. Reconstitution of reagents. > Molecular Devices LLC > 384 well plates. Powerful, benchtop microplate stacker that works seamlessly with Molecular Devices microplate readers and washers. Instrument settings are listed in Table 1. #R8190 (10) vials of component A*Instruments with a 96- or 384-well format will accommodate the most commonly used plates. The StakMax® Microplate Handling System is a powerful, compact, benchtop microplate stacker that works seamlessly with Molecular Devices microplate readers and washers for improved process flow and higher throughput. 25mm: Plate height:Absorbance was measured at 490 nm with SpectraMax Plus 384 plate reader (Molecular Devices, San Jose, CA). Get Quote . 2, prime the machine with CellTiter-Glo ® 2. x. For more sample throughput, the system canThe SpectraMax M5e Micoplate Reader is the standard for UV/Visible multi-mode reader absorbance, providing ultrafast, full spectral range detection for cuvettes, 96-well and 384-well microplates. Note: if all wells of a 384-well plate are to be read, the kinetic interval may need to be. They perform rapid throughput cell-based assays while. The Infinite 200 PRO is an easy-to-use multimode plate reader family that offers affordable, high performance detection solutions, referenced in more than 1800 peer reviewed publications. With optimized reagents, option to operate the. x. Microplate Readers. tools to expand the boundaries of their research. 2. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. The perfect microplate reader for everyday biochemical assays, cell-based assays, molecular biology and immunoassays. This user guide provides detailed instructions, troubleshooting tips and technical specifications for these instruments. Plate chamber design of the SpectraMax category 1 microplate readers. 2. Round well design with a clear flat bottom 2. Artel MVS Bundle DM Std/800TSNB Reader Details. Instrument settings can be saved as a protocol file and used repeatedly for reading different microplates or cuvettes. 96-well fluorescent cell dilution series, top-read. 384- or 96-well read plate containing cells loaded. Suitable for use in BMG lab tech, Molecular Devices, Promega Glomax and other plate readers; Suitable for adhesive and heat sealing: our Moisture Barrier Seal 384. This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent. MultiWash+ Microplate Washer. A2000 Full Wavelength Microplate Reader, 6 ~ 384 Well Plate, SHANGHAI PEIOU ANALYSIS INSTRUMENT CO. Tecan Infinite 200 Pro M Plex Microplate Reader Unit2 - AV. SpectraDrop Micro-Volume Microplate (Molecular Devices cat. Catalog number: BC1384W. The plate reader optics are tunable for. Infinite possibilities. Only Molecular Devices microplate plate readers offer the capability to measure the depth (optical. (or plate reader). Important things to consider when purchasing a multimode microplate reader. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. The SpectraMax ABS Plus reader utilizes Molecular . 00. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. That explains the lower values on the LmaxII384 plate reader. )Step 4: Incubate at room temperature for 1 hour, protected from light. 58% for the detection module and 2. Plate stacker and robot integration The SpectraMax M2 and M2e readers can be integrated with the StakMax® Microplate Stacker from Molecular Devices in a matter of minutes. Detailed thermal cycling conditions are listed in Table 2. #2704174, 2705402, 2705412, 2704180; Drummond Digital Microdispenser cat. ‘StimB’ is Stimulation Buffer, included in the IP-One Gq kit. All stand-alone instrument functions can be controlled using the software. Efficiency. Following the flushing of the machine as described in Section 3. 96/384-well plate formats. The purposes of the study were: 1) to determine the optimal wavelength settings for three cell lines. 9. Unlike conventional plate readers, multimode microplate readers are able to perform two or more forms of detection allowing a single piece of equipment to perform a wider range of assays. Products : SpectraMax 340PC 384 (Obsolete), SpectraMax Plus 384 reader. 00. An industry-renowned instrument for monitoring GPCRs and ion channels. 1. The fluid surface in a 384-well is a deeply curved meniscus. 5 ml microcentrifuge tubes 35 mm Petri dishes 12 mm × 50 mm test tubes (optional). Selects either 96-well or 384-well plate for a stand-alone read. Learn how to operate the VersaMax, SpectraMax 340PC384 and SpectraMax 190 Plus384 microplate readers, which offer fast and accurate absorbance measurements for a variety of assays. San Jose, Calif. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. The plate was mixed gently for 2 minutes on a plate shaker and then allowed to incubate at room temperature for 10 minutes to stabilize luminescence. Instruments with a 96- or 384-well format will accommodate the most commonly used plates. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. 384-WELL SBS STERILE MICROPLATE. *For Corning UV plates, mean values at 260 nm ranged from 0. Turn on Plate Reader and wait for it to complete its start-up routine. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. With SoftMax Pro Software, the PathCheck Sensor automatically normalizes the well absorbance. Add 100 µl (96-well plate) or 25 µl (384-well plate) of cell suspension to each well of poly-D-lysine coated plates. 314 low lamp level warning. Turn the reader on and secure the USB cable. molecular interaction studies, and nucleic acid quantification, as well. In addition, SoftMax Pro Software After incubation of the cells with compounds, add 100 µL (for 96-well plates) or 25 µL (for 384-well plates) of Dye Solution per test well. VMax . x. Tunable wavelength selection / monochromator. Read one sample or up to 384 in a single plate eead using any standard cuvette, or 96-or 384-well microplate. Dispense 10 µL of each ATP/ADP combination across an entire row of a 384-well plate. Both COC microplates, the μCLEAR UV STAR 96- and 384-well plates, had background absorbance of 1. 313 reference gain check fail. Temperature control: 4°C above ambient to 45°C. Instrument settings can be saved as a protocol file and used repeatedly for reading different microplates or cuvettes. The VICTOR® Nivo™ system packs all popular detection modes into the industry’s smallest multimode reader footprint. Polypropylene Deep well Plates are used as small test tubes because of easier sealing, flat or conical shape, square and round well formats with lids and cap. SpectraMax ID5 Plate Reader (Molecular Devices) Description Internal price (Cornell and Cornell affiliates) External Price; SpectraMax ID5 Plate Reader Use: $20/hr: $32/hr. Scan every well . 19 H mm that meet microplate industry standards. . With the FLIPR 384 , you get the sensitivity, data fidelity, and real-time, kinetic information of the FLIPR I system in a 384-well mode. SpectraMax i3x Microplate Reader, Molecular Devices (Cat# i3X) 96-well white walled clear bottom plates, Costar (Cat# 3903) Purified luciferase, Promega (Cat# E1701). Plate dimensions: X6001, X6004, X6011, X7001, X7007, X7020, X7022, X5101, X6026. easy to use and read multiple plates very quickly. Service parts for these models are not being produced and are no longer in stock. (Component A, C) is sufficient for 1 plate (96-, 384-, 1536-well). DynaPro ™ Plate Reader III. (40 µl maximum) Clear, white, or black. 0200-6263. This is equivalent to having 511 built-in filters, 384-well: 0. SpectraMax iD3 reader with touchscreen and inserted USB flash drive. The SpectraMax ABS/ABS Plus Microplate Readers provide fast absorbance detection without the use of filters with monochromator-based wavelength selection for visible and UV-visible absorbance. The instrument reads any standard cuvette, microcuvette, test tube or 96- and 384-well standard or UV transparent microplate over a full 190 to 1000. Page 1 of 8 . 7°C (gradient heating design). SpectraMax Mini Multi-Mode Microplate Reader (Molecular Devices P/N SMAX MINI AF), with fluorescence filter cube FL-535 (Molecular Devices P/N 5089097). , April 14, 2022 – Molecular Devices, LLC. EMax® Plus Microplate Reader, Molecular Devices Catalog Number: (10119-370) Supplier: Molecular Devices Description: Robust, high value microplate reader designed to. 7. Home > Search Results > Molecular Devices LLC > 384 well plate. The perfect microplate reader for everyday biochemical assays, cell-based assays, molecular biology and immunoassays. FLIPR Tetra systems are fluorescence- and luminescence-based microplate readers with an integrated 1536-, 384- or 96-pipettor. Figure 1. luminescence for a 96-well plate and 40 msec integration time for a 384-well plate. Two different agonists, acetylcholine and carbachol, were tested. x. Using Molecular Devices microplate readers and SoftMax. Use form “26003-02: Molecular Devices Plate Reader Plate Calibration Form” to record material and equipment information. Another consideration, says Amouretti, is plate format. The small-footprint Multiwash+ Microplate Washer quickly washes with both 96 and 384-well plates, has 20 standard wash protocols, and a simple LCD screen interface to customize speed, volume, soak time, and aspiration settings. 304 signal level saturation. EPOCH2 Plate Reader/Spectrophotometer. 4 decades . Nanoracks’ Plate-Reader-2 (2nd generation) is a reconfigured Molecular Devices SpectraMax M5e – one of the most reliable, durable, feature-rich microplate readers on the market. plated at 50,000 cells/well in 100 µL of DMEM/FBS in a 96-well plate and incubated at 37°C for five hours. The Standard Thermo Scientific 384-well plate, white, is compatible with the majority of 384 block PCR and sequencing instruments. The plate was mixed gently for 2 minutes on a plate shaker and then allowed to incubate at room temperature for 10 minutes to stabilize luminescence. All stand-alone instrument functions can be controlled using the software. This integrated system provides users with a multi-detection for the SpectraMax Multi-Mode Microplate Reader, as well as all other Molecular Devices' microplate readers. by a photomultiplier tube (PMT) or charge-coupled device (CCD) present within the plate reader. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection. #PLUS 384) UV-transparent 96-well microplates (Corning cat. Our multi-mode plate readers provide great flexibility and include absorbance, fluorescence and luminescence with configurable options for fluorescence polarization (FP), time. Analyst, M5, Flex 3, and SpectraMax L readers work differently. The SpectraMax L reader is easily integrated with the optional StakMax microplate stacker from Molecular Devices for automated multiplate assays. For nearly 30 years, Molecular Devices has provided scientists with . Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. The VICTOR Nivo. Explore the best practices for running absorbance-based assays how Molecular Devices absorbance readers can be utilized to optimize said absorbance-based assays. Supplier: Molecular Devices. 20 attomol ATP per well. SpectraDrop High-Throughput Screening (HTS) Kit. 7. SpectraMax iD5 Multi-Mode Microplate Reader (Molecular Devices cat. The instrument reads any standard cuvette, microcuvette, test tube or 96- and 384-well standard or UV transparent microplate over a full 190 to 1000. The color touch screen provides a visual user interface, making programming fast and intuitive. From the Windows Start menu, go to All programs > Molecular Devices > SoftMax Pro x. More Product Information. 76 L x 85. ability to use as little as 2˜µL samples with 24- or 64-well plates. Enable more assay conditions Define individual reagents to be delivered to each well reducing reagent consumption and allowing for more assay conditions to be explored on a single microplate. ) 45 (W) x 70 (H) x 27 (D) Dimensions (cm) 114 (W) x 178. 2. 12, 24, 96 & 384-well SBS microplates; Range of 96, 384-well SBS microplates . We would like to show you a description here but the site won’t allow us. #6590-0118) Filter 665/10 (Molecular Devices cat. In these readers, RLUs are proportional to counts/sec which doesn't change with integration time assuming the. 1 or 10 Tablet PC with USB connection to instrument: Read Speed: 96-well plate: less than 1 minute; 384-well plate: less than 3 minutes: Automation Compatibility: Hardware and software accessible to third-party hardware/software control, including LIMS. readers are the industry’s most cited instruments and have empowered life science researchers to advance protein and cell biology, breaking the barriers to novel, landmark discoveries. After reading the ELISA plate on both readers, each standard curve was nearly identical. changes in OD 600 were measured by periodically transferring 100-µL aliquots of each bacterial culture to a single well of a 96-well microplate and measuring absorbance at 600 nm using the SpectraMax iD3 reader and SoftMax Pro Software. 2. Transfer the assay plate directly to a bottom-read fluorescence microplate reader for kinetic read-mode or incubate for 10-30 min at 37oC and then read for endpoint read-mode. Reader SpectraMax® Paradigm® Multi-Mode Microplate Reader. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate. VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. The eight-channel system delivers both high precision and speed when reading 96- and 384-well microplates for endpoint measurements, kinetic assays, and spectral scans. 5577. When reading at wavelengths below 340 nm, special UV-transparent, disposable or quartz microplates andCompany Molecular Devices, LLC; Price Get Quote; Catalog Number CSI / CSI FL; Type Cell Imaging System; Measuring Time White light - 96-well/ 384 well microplate: <2 min Fluorescence - 96-well/ 384 well microplate: <8 min; Plate Formats 6, 12, 24, 96 & 384-well SBS microplates; Applications Cell Line Development, Fluorescence, Time-LapseNext-generation luminescence plate reader. , a leading provider of high-performance life science solutions and a company of Danaher Corporation (NYSE:DHR), has today. Both readers were heated to 37ºC prior to setting up the assay. Gemini EM Reader scans. Related products. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. Molecular Devices: n/a:. (1536-well plate) 2 µL (quartz cuvette), 4 µL (disposable cuvette). Simultaneous dual emission detection enables read times of only 2:17 for an entire 384-well plate. Some instruments can handle only 96-well plates and lower, whereas others can read up to the ultrahigh throughput densities of 1,536-well plates. A preconfigured protocol with optimized reader settings enabled reading of a 384-well plate in just two minutes. Packed 25 plates per sleeve, 2 sleeves per case. 5 fg per well to 0. Outer wells aligned for proper viewing with FLIPR Ideal.